This paper describes a novel solution for the active locomotion of a miniaturized endoscopic capsule in the gastrointestinal (GI) tract. In particular, the authors present the design, development, and testing of a legged locomotion system embedded in a capsule (with a volume of about 4–5 cm3 ) and actuated by a brushless minimotor. The actuation mechanism and transmission mechanism are described in detail in order to highlight the compactness of the overall design. This device is provided with four superelastic legs, allowing large stroke advancement in the GI tract, and a CMOS frontal camera, for diagnostic purposes. A dedicated electronic board for controlling the opening angle of the legs and adjusting their speed has been developed. In order to investigate the motion ability of the device, a set of experiments has been carried out. Four different types of superelastic legs have been designed and tested with the objective to identify the best leg configuration for capsule locomotion. Experimental results demonstrate that the device can travel in the digestive tract with a typical speed ranging between 10 and 40 mm/min.

Design and Fabrication of a Motor Legged Capsule for the Active Exploration of the Gastrointestinal Tract

MENCIASSI, Arianna;STEFANINI, CESARE;DARIO, Paolo
2008-01-01

Abstract

This paper describes a novel solution for the active locomotion of a miniaturized endoscopic capsule in the gastrointestinal (GI) tract. In particular, the authors present the design, development, and testing of a legged locomotion system embedded in a capsule (with a volume of about 4–5 cm3 ) and actuated by a brushless minimotor. The actuation mechanism and transmission mechanism are described in detail in order to highlight the compactness of the overall design. This device is provided with four superelastic legs, allowing large stroke advancement in the GI tract, and a CMOS frontal camera, for diagnostic purposes. A dedicated electronic board for controlling the opening angle of the legs and adjusting their speed has been developed. In order to investigate the motion ability of the device, a set of experiments has been carried out. Four different types of superelastic legs have been designed and tested with the objective to identify the best leg configuration for capsule locomotion. Experimental results demonstrate that the device can travel in the digestive tract with a typical speed ranging between 10 and 40 mm/min.
2008
File in questo prodotto:
File Dimensione Formato  
quirinitmech2008.pdf

non disponibili

Tipologia: Documento in Post-print/Accepted manuscript
Licenza: Non pubblico
Dimensione 622.38 kB
Formato Adobe PDF
622.38 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11382/4534
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 144
social impact