Background: Recent studies suggested that there are marked systematic differences among BNP immunoassays. In this study we compared the BNP data and clinical results obtained with different immunoassays, including a new method (ST-AIA-PACK, TOSOH Corporation). Methods: BNP was measured on plasma-EDTA samples of healthy subjects (HS, n = 126) and patients with heart failure (HF, n = 31 NYHA I, II; n = 46 NYHA III, IV) using the ST-AIA-PACK and the Triage Biosite (Beckman Coulter) methods. Control samples distributed in the CardioOrmoCheck external quality assessment were also measured with TOSOH and the most used BNP immunoassays in Italy. Results: TOSOH method showed a good correlation (R = 0.976; n = 327) but a mean bias (−46.9%) compared to Triage Biosite. On the base of the results obtained in 10 samples of the CardioOrmoCheck study, TOSOH method showed a strict agreementwith ADVIA Centaur, while it underestimated BNP in comparisonwith Triage (−52.5%) and ARCHITECT methods (−39.4%). The agreement of ST-AIA-PACK and Triage Biosite methods for classification of HF patients was tested using 100 ng/L of BNP; the positive agreement between methods was 65%, overall agreement was 73%. Conclusions: Our results confirm that there are marked differences in measured values among commercial methods for BNP assay.

Systematic differences between BNP immunoassays: comparison of methods using standard protocols and quality control materials

FRANZINI, Maria;MASOTTI, Silvia;PASSINO, Claudio;CLERICO, ALDO
2013-01-01

Abstract

Background: Recent studies suggested that there are marked systematic differences among BNP immunoassays. In this study we compared the BNP data and clinical results obtained with different immunoassays, including a new method (ST-AIA-PACK, TOSOH Corporation). Methods: BNP was measured on plasma-EDTA samples of healthy subjects (HS, n = 126) and patients with heart failure (HF, n = 31 NYHA I, II; n = 46 NYHA III, IV) using the ST-AIA-PACK and the Triage Biosite (Beckman Coulter) methods. Control samples distributed in the CardioOrmoCheck external quality assessment were also measured with TOSOH and the most used BNP immunoassays in Italy. Results: TOSOH method showed a good correlation (R = 0.976; n = 327) but a mean bias (−46.9%) compared to Triage Biosite. On the base of the results obtained in 10 samples of the CardioOrmoCheck study, TOSOH method showed a strict agreementwith ADVIA Centaur, while it underestimated BNP in comparisonwith Triage (−52.5%) and ARCHITECT methods (−39.4%). The agreement of ST-AIA-PACK and Triage Biosite methods for classification of HF patients was tested using 100 ng/L of BNP; the positive agreement between methods was 65%, overall agreement was 73%. Conclusions: Our results confirm that there are marked differences in measured values among commercial methods for BNP assay.
2013
File in questo prodotto:
File Dimensione Formato  
2013g BNP TOSOH comparison.pdf

accesso aperto

Tipologia: Documento in Post-print/Accepted manuscript
Licenza: PUBBLICO - Pubblico con Copyright
Dimensione 688.09 kB
Formato Adobe PDF
688.09 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11382/407873
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 29
social impact