In this paper, we present an approach to the online implementation of a gait event detector based on machine learning algorithms. Gait events were detected using a uniaxial gyro that measured the foot instep angular velocity in the sagittal plane to feed a four-state left-right hidden Markov model (HMM). The short-time Viterbi algorithm was used to overcome the limitation of the standard Viterbi algorithm, which does not allow the online decoding of hidden state sequences. Supervised learning of the HMM structure and validation with the leave-one-subject-out validation method were performed using treadmill gait reference data from an optical motion capture system. The four gait events were foot strike, flat foot (FF), heel off (HO), and toe off. The accuracy ranged, on average, from 45 ms (early detection, FF) to 35 ms (late detection, HO); the latency of detection was less than 100 ms for all gait events but the HO, where the probability that it was greater than 100 ms was 25%. Overground walking tests of the HMM-based gait event detector were also successfully performed.

Online Decoding of Hidden Markov Models for Gait Event Detection Using Foot-Mounted Gyroscopes

MANNINI, ANDREA;GENOVESE, Vincenzo;SABATINI, Angelo Maria
2014-01-01

Abstract

In this paper, we present an approach to the online implementation of a gait event detector based on machine learning algorithms. Gait events were detected using a uniaxial gyro that measured the foot instep angular velocity in the sagittal plane to feed a four-state left-right hidden Markov model (HMM). The short-time Viterbi algorithm was used to overcome the limitation of the standard Viterbi algorithm, which does not allow the online decoding of hidden state sequences. Supervised learning of the HMM structure and validation with the leave-one-subject-out validation method were performed using treadmill gait reference data from an optical motion capture system. The four gait events were foot strike, flat foot (FF), heel off (HO), and toe off. The accuracy ranged, on average, from 45 ms (early detection, FF) to 35 ms (late detection, HO); the latency of detection was less than 100 ms for all gait events but the HO, where the probability that it was greater than 100 ms was 25%. Overground walking tests of the HMM-based gait event detector were also successfully performed.
2014
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11382/416711
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 98
social impact