Permanent implantation of electrodes for prosthetic control is now possible using an osseointegrated implant as a long-term stable communication interface (e-OPRA). The number of myoelectric sites to host such electrodes can be increased by Targeted Muscle Reinnervation (TMR). Traditionally, patients need to wait several months before the TMR signals are strong enough to be recorded by electrodes placed over the skin. In this study, we report the evolution of the TMR myoelectric signals recorded from two subjects via implanted electrodes using e-OPRA, and monitored for up to 48 weeks after surgery. The signals were analyzed with regard to amplitude (signal-to-noise ratio), independence (cross-correlation) and myoelectric pattern recognition (classification accuracy). TMR signals appeared at the first follow-up, one month post-surgery, and developed around 20 dB by the last. Cross-correlation between signals decreased over time and converged to a few percentage points. Classification accuracies were over 97% by the last follow up. These preliminary results suggest that implanted electrodes via the e-OPRA interface allow for an earlier and more effective use of motor signals from TMR sites compared to conventional skin surface electrodes.

Myoelectric signals and pattern recognition from implanted electrodes in two TMR subjects with an osseointegrated communication interface

Mastinu E.;
2018-01-01

Abstract

Permanent implantation of electrodes for prosthetic control is now possible using an osseointegrated implant as a long-term stable communication interface (e-OPRA). The number of myoelectric sites to host such electrodes can be increased by Targeted Muscle Reinnervation (TMR). Traditionally, patients need to wait several months before the TMR signals are strong enough to be recorded by electrodes placed over the skin. In this study, we report the evolution of the TMR myoelectric signals recorded from two subjects via implanted electrodes using e-OPRA, and monitored for up to 48 weeks after surgery. The signals were analyzed with regard to amplitude (signal-to-noise ratio), independence (cross-correlation) and myoelectric pattern recognition (classification accuracy). TMR signals appeared at the first follow-up, one month post-surgery, and developed around 20 dB by the last. Cross-correlation between signals decreased over time and converged to a few percentage points. Classification accuracies were over 97% by the last follow up. These preliminary results suggest that implanted electrodes via the e-OPRA interface allow for an earlier and more effective use of motor signals from TMR sites compared to conventional skin surface electrodes.
2018
978-1-5386-3646-6
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11382/550459
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 18
social impact